Guardrail of Frontline

Phase / Section / Heading Rule Number Frontline Rule Applicable Platforms Additional Information / Comments Ticket Number Date Added Date Modified
Historical Rules 1 Encrypted and Non-Encrypted Drives Mixing not allowed
To include NVMe SED also – post GA item in G9
All G10 Platforms, All G9 Platforms, All G8 Platforms NA (Carry forward)
Historical Rules 2 Total drive count should be within Min and Max drive slots available for the model depending on drive configuration
HDD + SSD, NVMe+SSD, All NVMe, NVMe Advanced, NVMe Advanced + NVMe

Mar 4 : G10 Drive configs: All NVMe & NVMe + SSD will be renamed to NVMe All Flash since there is no NVMe + SSD supported in G10

All G10 Platforms, All G9 Platforms, All G8 Platforms NA (Carry forward)
Historical Rules 3 HDD:SSD ratio >= 2:1 for models having Max drive slot > 4 (except 1175S) All G10 Platforms, All G9 Platforms, All G8 Platforms Override functionality available | CPQ-5559 NA (Carry forward)
Historical Rules 20 NX-3155G-G7 – For This model, GPU is not mandatory, means user should be able to add Model without adding any GPU
In G9, the platform name will be 3155
NX-3155G-G8, NX-3155-G9 BA-81824
NPI-764
Historical Rules 31 System flag = TRUE and Selected = FALSE then mark it as invalid option All G10 Platforms, All G9 Platforms, All G8 Platforms NA (Carry forward)
Historical Rules 32 External ID ends with model type string, then option is limited to that model type only (AF, HY, NVME)
Impact analysis for G9 to be done as G9 drive configurations are different. Details in BRD.
All G10 Platforms, All G9 Platforms, All G8 Platforms NA (Carry forward)
Historical Rules 33 Quote visibility controls availability of options based on logged in user’s role All G10 Platforms, All G9 Platforms, All G8 Platforms NA (Carry forward)
Historical Rules 34 CPU, RAM and Drive are mandatory for blocks
Feb 18: Exception to the above rule is the newly introduced compute only model type
All G10 Platforms, All G9 Platforms, All G8 Platforms NA (Carry forward)
Historical Rules 35 NIC ABL countries = Algeria, Afghanistan, Bangladesh, Brunei, Chad, Iraq, Kuwait, Lebanon, Libya, Malaysia, Mali, Pakistan, Qatar, Saudi Arabia, Yemen
Based on install country and shipping country and end customer country nics are removed based on the following matrix

Table link – https://docs.google.com/spreadsheets/d/1qRbFqpCxwChvrei39URlF9Bce6cKmLIYLHi9_PQTzdY/edit?gid=1085857383#gid=1085857383&range=A2:A4

All G10 Platforms, All G9 Platforms, All G8 Platforms NA (Carry forward)
NPI-383
NPI-47
Historical Rules 36 PSU – Based on Install Country, if install country is absent use Billing Country.

Table Link – https://docs.google.com/spreadsheets/d/1qRbFqpCxwChvrei39URlF9Bce6cKmLIYLHi9_PQTzdY/edit?gid=1085857383#gid=1085857383&range=B7:B11

Exception of U-PSU-2200-TR2.This rule should not apply to U-PSU-2200-TR2 from G8 onwards.
No geography based restrictions for any PSU SKUs apart from the ones mentioned in table

All G10 Platforms, All G9 Platforms, All G8 Platforms BA-81162
BA-8296
Historical Rules 37 `+2 months support is not allowed for quotes that is outside “Americas” region except “Brazil” – in other words +2 months should be available everywhere outside Americas and also in Brazil even if region is Americas All G10 Platforms, All G9 Platforms, All G8 Platforms NA (Carry forward)
Historical Rules 38 Appliance support is not allowed on NX Core quote All G8 Platforms NA (Carry forward)
Historical Rules 39 Hardware support is not allowed on NX Appliance quote All G8 Platforms NA (Carry forward)
Historical Rules 40 Max appliance support discount is 40% All G10 Platforms, All G9 Platforms, All G8 Platforms NA (Carry forward)
Historical Rules 41 Default Hardware support discount is 20% and max is 40% All G10 Platforms, All G9 Platforms, All G8 Platforms NA (Carry forward)
Historical Rules 42 Product options without category 1, category 2, category 3 and category 4 are removed All G10 Platforms, All G9 Platforms, All G8 Platforms NA (Carry forward)
Historical Rules 43 SED drives are not allowed if the install country belongs to any of the following countries *[“Cuba”, “Iran (Islamic Republic of)”, “Ukraine”, “Syrian Arab Republic”,* Armenia”, “Belarus”, “Kazakhstan”, “Kyrgyzstan”, “Russian Federation”]

CPQ-7062 – Countries names updated

All G10 Platforms, All G9 Platforms, All G8 Platforms CPQ-4095
CPQ-7062
Historical Rules 44 Federal support is not available outside “Americas USA Federal” sub theater on account All G10 Platforms, All G9 Platforms, All G8 Platforms NA (Carry forward)
Historical Rules 48 Mission Critical Support is based on the install address of the node All G10 Platforms, All G9 Platforms, All G8 Platforms NA (Carry forward)
Historical Rules 49 Discount on NRDK cannot exceed 40% All G10 Platforms, All G9 Platforms, All G8 Platforms NA (Carry forward)
Historical Rules 50 Sales rep cannot quote standalone NRDK All G10 Platforms, All G9 Platforms, All G8 Platforms NA (Carry forward)
Historical Rules 51 `+2 months support for NRDK is available opportunity region is “APAC” or “EMEA” or subRegion is “Americas Latin America All G10 Platforms, All G9 Platforms, All G8 Platforms NA (Carry forward)
Historical Rules 52 Nutanix Hardware Cannot be Quoted on HPE Quote All G10 Platforms, All G9 Platforms, All G8 Platforms NA (Carry forward)
Historical Rules 53 Upgrades/spares cannot be intermixed with other products on Brazil quote All G10 Platforms, All G9 Platforms, All G8 Platforms NA (Carry forward)
Historical Rules 54 TPM is not supported for the following countries [“Cuba”, “Iran (Islamic Republic of)”, “Ukraine”, “Armenia”, “Belarus”, “Kazakhstan”,
“Kyrgyzstan”, “Russian Federation”, “Syrian Arab Republic”]

CPQ-7062- Countries names updated

All G10 Platforms, All G9 Platforms, All G8 Platforms CPQ-4095
CPQ-7062
Historical Rules 55 Ultimate license or encryption add-on is required for adding SED drives

For new portfolio quote:
Ultimate license (NCI/NCI-D/EUC ULT) or security addon (NCI/NCI-D/NUS Security) is required for adding SED drives

Needs to apply for NVMe SED also in future (post GA item for G9)

14-Jul-2025 update (change with AOS 7.3)-
Ultimate license or Pro license or NUS-Starter+Security Add-On is required for adding SED drives

For new portfolio quote:
Ultimate license (NCI/NCI-D/EUC/NKP-FS/NCI-E/NAI-GPT) or Pro license (NCI/NCI-D/EUC/NKP-FS/NCI-E/NUS-Pro/NAI-GPT) or NUS Starter (NUS-STR) with security add-on (NUS) is required for adding SED drives

Needs to apply for NVMe/SSD/HDD SEDs also

The additional security add-on is only required for NUS Starter. It is not required for the mentioned Ultimate or Pro licenses

All G10 Platforms, All G9 Platforms, All G8 Platforms Override functionality required (WIP – NPI-810)
Has to be applied to (SSE, HDE both and NVMe SED for post GA in G9)
NA (Carry forward)
NPI-436
NPI-1573
7/24/2025
Historical Rules 57 Operating Temperature rules for G8 Platforms. Need to display operating temperature message, based on TDP values as per below table.

The configuration should be quotable but the warning message must be displayed.

Table Link – https://docs.google.com/spreadsheets/d/1qRbFqpCxwChvrei39URlF9Bce6cKmLIYLHi9_PQTzdY/edit?gid=1085857383#gid=1085857383&range=B14:B18

All G8 Platforms, NX-3060-G8, NX-1065-G8, NX-8035-G8 BA-81162
Historical Rules 58 Operating Temperature rules for G8 Platforms. Need to display operating temperature message, based on TDP values as per below table.

The configuration should be quotable but the warning message must be displayed.

Table Link – https://docs.google.com/spreadsheets/d/1qRbFqpCxwChvrei39URlF9Bce6cKmLIYLHi9_PQTzdY/edit?gid=1085857383#gid=1085857383&range=B21

All G8 Platforms, NX-8155-G8 BA-81823
Historical Rules 59 Memory + Processor constraints for G8 Platforms. Need to display below message, based on TDP values as per below table and also block the config.
The configuration should NOT be quotable and the error message must be displayed.

Table Link – https://docs.google.com/spreadsheets/d/1qRbFqpCxwChvrei39URlF9Bce6cKmLIYLHi9_PQTzdY/edit?gid=1085857383#gid=1085857383&range=B24

All G8 Platforms, NX-8170-G8 BA-81823
Historical Rules 60 Memory + Processor constraints for G8 Platforms. Need to display below message, based on TDP values as per below table and also block the config.
The configuration should NOT be quotable and the error message must be displayed.

Table Link – https://docs.google.com/spreadsheets/d/1qRbFqpCxwChvrei39URlF9Bce6cKmLIYLHi9_PQTzdY/edit?gid=1085857383#gid=1085857383&range=B27

All G8 Platforms, NX-3170-G8 BA-81824
Historical Rules 61 GPU & NIC related option constraints for Platform NX-3155G-G8.
Please note that these rules should apply only to Nvidia T4 GPU (C-GPU-T4-16GB). There will be separate rules for different GPU models (Post GA)

Table Link – https://docs.google.com/spreadsheets/d/1qRbFqpCxwChvrei39URlF9Bce6cKmLIYLHi9_PQTzdY/edit?gid=1085857383#gid=1085857383&range=B30:B32

NX-3155G-G8 BA-81824
Historical Rules 62 CPU + Memory constraints for G8 Platforms.
The configuration should NOT be quotable and the error message must be displayed.

Table Link – https://docs.google.com/spreadsheets/d/1qRbFqpCxwChvrei39URlF9Bce6cKmLIYLHi9_PQTzdY/edit?gid=1085857383#gid=1085857383&range=B35

All G8 Platforms, NX-3060-G8 BA-81162
Historical Rules 66 Existing Portfolio:
The configuration should NOT be quotable and the error message must be displayed.
(Config and error message in the table link below under “Existing Portfolio” rows)

New Portfolio:
The configuration SHOULD BE quotable and the warning message must be displayed.
(Config and error message in the table link below under “New Portfolio” rows)

Table Link – https://docs.google.com/spreadsheets/d/1qRbFqpCxwChvrei39URlF9Bce6cKmLIYLHi9_PQTzdY/edit?gid=1085857383#gid=1085857383&range=B39:B42

All G10 Platforms, All G9 Platforms, All G8 Platforms Override functionality available | CPQ-5559 BA-81824
NPI-436
Historical Rules 67 The configuration should NOT be quotable and the error message must be displayed

Table Link – https://docs.google.com/spreadsheets/d/1qRbFqpCxwChvrei39URlF9Bce6cKmLIYLHi9_PQTzdY/edit?gid=1085857383#gid=1085857383&range=B45:B46

All G10 Platforms, All G9 Platforms, All G8 Platforms Override functionality available | CPQ-5559 BA-81824
NPI-436
NPI-1015
Historical Rules 70 Operating Temperature rules for G8 Platforms. Need to display operating temperature message, based on TDP values as per below table.

The configuration should be quotable but the warning message must be displayed.

Table Link – https://docs.google.com/spreadsheets/d/1qRbFqpCxwChvrei39URlF9Bce6cKmLIYLHi9_PQTzdY/edit?gid=1085857383#gid=1085857383&range=B49

All G8 Platforms, NX-8150-G8 NPI-214
Historical Rules 71 GPU-related option constraint (3155G)
The configuration should be quotable but the warning message must be displayed.

Table Link – https://docs.google.com/spreadsheets/d/1qRbFqpCxwChvrei39URlF9Bce6cKmLIYLHi9_PQTzdY/edit?gid=1085857383#gid=1085857383&range=B52

NX-3155G-G8 NPI-333
NPI-349
Historical Rules 72 GPU & NIC-related option constraints for Platform NX-3155G-G8.

Table Link – https://docs.google.com/spreadsheets/d/1qRbFqpCxwChvrei39URlF9Bce6cKmLIYLHi9_PQTzdY/edit?gid=1085857383#gid=1085857383&range=B55:B56

GPU impacted – All GPUs starting with “C-GPU-A”, L40S (C-GPU-L40S-48GB,C-GPU-L40S-48GB-CM )

GPU Quantity Selected – NIC Quantity Supported – Message
* 1x GPU – 1x, 2x, 3x NICs –
* 2x GPU – 1x, 2x NICs – Maximum 2 NICs supported with 2 quantity of <GPU Name>

NX-3155G-G8 NPI-238
NPI-349
NPI-946
Historical Rules 74 GPU & NIC related option constraints for Platform NX-3155G-G8.
Please note that these rules should apply only to Nvidia A2 GPU (C-GPU-A2-16GB)

Table Link – https://docs.google.com/spreadsheets/d/1qRbFqpCxwChvrei39URlF9Bce6cKmLIYLHi9_PQTzdY/edit?gid=1085857383#gid=1085857383&range=B59:B61

GPU Quantity Selected – NIC Quantity Supported – Message
* 1x GPU – 1x, 2x, 3x NICs –
* 2x, 3x, or 4x GPU – 1x , 2x NICs – Maximum 2 NICs supported with 2, 3 or 4 quantity of NVIDIA A2 GPU (16GB)
* 5x GPU – 1x NICs – Only 1 NIC supported with 5 quantity of Nvidia A2 GPU (16GB)

NX-3155G-G8 NPI-427
Historical Rules 75 GPU-related option constraint for Platform NX-3155G-G8.

Please note: If GPU with SKU: C-GPU-A2-16GB is selected Rule 71 and 72 should not trigger.

NX-3155G-G8 NPI-427
Historical Rules 76 GPU-related option constraint for Platform NX-3155GN-G8.

This rule applies to T4 and A2 GPUs only

Table Link – https://docs.google.com/spreadsheets/d/1qRbFqpCxwChvrei39URlF9Bce6cKmLIYLHi9_PQTzdY/edit?gid=1085857383#gid=1085857383&range=B64:B66

NX-3155GN-G8 NPI-510
NPI-591
Historical Rules 77 Platform: 3155GN-G8 | This rule applies only to A series GPUs (except A2)

Table Link – https://docs.google.com/spreadsheets/d/1qRbFqpCxwChvrei39URlF9Bce6cKmLIYLHi9_PQTzdY/edit?gid=1085857383#gid=1085857383&range=B69:B70

Rules 71 and 73 also apply to all A series GPUs (except A2)

NX-3155GN-G8 NPI-510
Historical Rules 82 GPU & Country related constraints

Table Link – https://docs.google.com/spreadsheets/d/1qRbFqpCxwChvrei39URlF9Bce6cKmLIYLHi9_PQTzdY/edit?gid=1085857383#gid=1085857383&range=B73

Also refer to changes via BA-103927

All G10 Platforms, All G8 Platforms NPI-673 (Demand shaping)
BA-103927
Historical Rules 83 NVMe + SSD mixing restrictions:

Only configurations with equal NVMe SSD & SATA/SAS SSD capacities are to be supported.

Applicable to all HW quotes, irrespective of the Software (HCI / NCI / NUS / Files etc.. ) selected.

Example:
Supported: Combination of 7.68TB NVMe with 7.68 SATA/SAS SSD is supported
Not Supported: Combination of 1.92TB NVMe with 7.68 SATA/SAS SSD is not supported

All G10 Platforms, All G9 Platforms, All G8 Platforms Override functionality for exception | NPI-770 NPI-713
Historical Rules 84 PSU to CPU mapping defined in G8 for 3060-G8 All G8 Platforms PSU is not a C-SKU in G9 BA-80037
Historical Rules 85 PSU to Power cord mapping defined in G8 for 3060-G8 All G8 Platforms PSU is not a C-SKU in G9 BA-80037
Historical Rules 86 Power cord to Country mapping defined in G8 including RoW countries

Link – https://docs.google.com/document/d/14mW2E3ejnARb1CRAOQ8Aha8TuBAY-RXWWU_bVVuLEHI/edit?tab=t.0

All G10 Platforms, All G9 Platforms, All G8 Platforms BA-80037,
NPI-317
Historical Rules 87 NG8 NIC intermixing rules defined as part of NG8: BRD (Phase 1 & Phase 2) All G8 Platforms Phase 1 & 2 are irrelevant for G9 as C-LOM is an option for G9 NPI-506, NPI-510
Historical Rules 88 NG8 BRD – Phase 3 – Req. 9 – Intermixing rules for LOM-NIC (#1)
Big Twins when LOM is NONE
Same rules as in Phase 1 with one exception below
C-NIC-10G2D1BT not a valid option for AOC 1, 2, 3 (should not show up in dropdown)
Big Twins when LOM is “C-LOM-10G2D1BT” (CM & non-CM SKUs):
C-NIC-10GBT2-A and C-NIC-10GBT2-A-Q are not valid options for AOC 1, 2, 3 (should not show up in dropdown)
All G8 Platforms Rule irrelevant for G9 as C-LOM-NONE is not an option for G9 NPI-540
Historical Rules 89 NG8 BRD – Phase 3 – Req. 9 – Intermixing rules for LOM-NIC (#2)
Big Twins when LOM is “C-LOM-10G2D1BT” (CM & non-CM SKUs):
C-NIC-10GBT2-A and C-NIC-10GBT2-A-Q are not valid options for AOC 1, 2, 3 (should not show up in dropdown)
All G9 Platforms, All G8 Platforms Rule to be extended to ALL G9 platforms NPI-540
Historical Rules 90 NG8 BRD – Phase 3 – Req. 8, 10, 11 All G8 Platforms C-LOM is an option in G9 – but other messaging related changes not required in G9 NPI-540
Historical Rules 91 NG8 Big Twins when LOM is “C-LOM-10G2B1BT” (CM & non-CM SKUs):
C-NIC-10G2D1BT is not a valid option for Add-on card NIC (Networking section in FL – should not show in the dropdown for the aforementioned LOM) – BRD
All G9 Platforms, All G8 Platforms Rule to be extended to ALL G9 platforms NPI-766
NPI-992
NPI-993
Historical Rules 92 AOS 6.5.1 Capacity rules – BRD All G9 Platforms, All G8 Platforms Override functionality for min capacity and partial pop rules NPI-735
Historical Rules 93 NIC Card: C-NIC-25G4E1/-CM SKU should NOT be quotable in non-ALB countries for G8 platforms. NIC Country of Origin: Non-Israel.

In G9 platforms – the SKU should follow generic rules and be quotable in ALL countries (no guardrails) as COO is non-Israel

All G8 Platforms G8 RULE ONLY CPQ-9240
Historical Rules 94 8155:
For “NOT No snapshot” (i.e. RPO-1 Hr or RPO-6Hr) OR Files Dedicated OR Objects Dedicated OR NUS Dedicated chosen
For 8 TB HDD capacity, <SSD or NVMe> with a capacity greater than 1.92 TB <SSD or NVMe> required on 8155 partially configured node.

Message: “For 8 TB HDD capacity, 1.92 TB<SSD or NVMe> capacity is allowed on 8155 partially configured node only with no snapshots.”

If “No snapshot” is chosen – this rule should not apply.

Note: Messaging should say NVMe or SSD based on drive selected as G9 will have NVMe+HDD as Hybrid configuration for 8155
NOTE: The rule should apply to HDEs, SSEs (NVMe SED for G9) too.

27Mar2025: NOTE: The rule should apply to HDEs, SSEs (NVMe SED for G9) & NVE too.

All G9 Platforms, All G8 Platforms, All G10 Platforms Override functionality available| NPI-735 NPI-735
Historical Rules 95 8155:
For “NOT No snapshot” (i.e. RPO-1 Hr or RPO-6Hr)
For 12 TB HDD capacity, <SSD or NVMe> with a capacity greater than 1.92 TB 3.84 <SSD or NVMe> required on 8155 partially configured node.

Message: “For 12 TB HDD capacity, <SSD or NVMe> with a capacity greater than 3.84 TB <SSD or NVMe> required on 8155 partially configured node with snapshots.”

If “No snapshot” is chosen OR Files Dedicated OR Objects Dedicated OR NUS Dedicated
For 12 TB HDD capacity, <SSD or NVMe> with a capacity greater than 1.92 TB <SSD or NVMe> required on 8155 partially configured node.

Message: “For 12 TB HDD capacity, <SSD or NVMe> with a capacity greater than 1.92 TB <SSD or NVMe> required on 8155 partially configured node.”

Note: Messaging should say NVMe or SSD based on drive selected as G9 will have NVMe+HDD as Hybrid configuration for 8155.

NOTE: The rule should apply to HDEs, SSEs (NVMe SED for G9) too.

27Mar2025: NOTE: The rule should apply to HDEs, SSEs (NVMe SED for G9) & NVE too.

All G9 Platforms, All G8 Platforms, All G10 Platforms Override functionality available| NPI-735 NPI-735
Historical Rules 96 For Hybrid configurations (HDD + SSD / HDD +NVMe)

If “No snapshot” replication requirement
-If node capacity <=136TB, SSD (NVMe for G9) capacity should be a minimum of 4% of Total capacity
-If node capacity > 136 TB, SSD (NVMe for G9) capacity should be a minimum of 10% of Total capacity

If NOT “No snapshot” replication requirement
-If node capacity <=60 TB, SSD (NVMe for G9) capacity should be a minimum of 4% of Total capacity
-If node capacity > 60 TB, SSD (NVMe for G9) capacity should be a minimum of 10% of Total capacity

If NUS Dedicated OR Objects Dedicated OR Files Dedicated OR HW only quote with Dedicated NUS chosen: SSD (NVMe for G9) capacity should be a minimum of 6% of Total capacity

Exceptions to the rule:
8155: Below configurations should be allowed in FL as exceptions:
10*6TB HDD / HDE + 2*1.92TB SSD / SSE (NVMe for G9)
10*8TB HDD / HDE + 2*3.84TB SSD / SSE (NVMe for G9)

8155: Below configurations should be allowed in FL as exceptions with “No Snapshot” ONLY:
8*18TB HDD / HDE+ 2*7.68TB SSD / SSE (NVMe for G9)
10*18TB HDD / HDE + 2*7.68TB SSD / SSE (NVMe for G9)

NOTE: The rule should apply to HDEs, SSEs (NVMe SED for G9) too.

27Mar2025: The following Exceptions have been added
3155: Below configuration should be allowed in FL as exceptions:
4*18TB HDD + 2*3.84TB NVMe

3035: Below configuration should be allowed in FL as exceptions:
4*18TB HDD + 2*3.84TB SSD / NVME
NOTE: The rule should apply to HDEs, SSEs, NVEs too.

All G9 Platforms, All G8 Platforms, All G10 Platforms Override functionality available| NPI-735 NPI-735
Historical Rules 97 For “NOT No Snapshot” (i.e. RPO-1 Hr, RPO-6 Hr)
8155: 18 TB HDD capacity is not supported.
Message: “18 TB HDD capacity is not supported on 8155 with snapshots.”

For “No snapshot” OR Files Dedicated OR Objects Dedicated OR NUS Dedicated
For 18 TB HDD capacity, SSD (NVMe for G9) with a capacity greater than 3.84 TB SSD (NVMe for G9) required on 8155 partially configured node.
Message same as rule.

Note: Messaging should say NVMe or SSD based on drive selected as G9 will have NVMe+HDD as Hybrid configuration for 8155

NOTE: The rule should apply to HDEs, SSEs too.

27Mar2025: NOTE: The rule should apply to HDEs, SSEs (NVMe SED for G9) & NVE too.

All G9 Platforms, All G8 Platforms, All G10 Platforms Override functionality available| NPI-735 NPI-735
Historical Rules 98 When the CPU which is not Energy Star compliant for a particular platform is selected then fire the below warning message
“Please note <CPU name> is excluded from Energy Star certification for <Platform Name>”
All G10 Platforms, All G9 Platforms Applicable for NX-G9 for now and will extend to NX-G8 also in future NPI-900
NPI-1015
NPI-1439
Historical Rules 99 Below message should fire in Frontline UI Summary page:
TPM 2.0 is offered as a security hardware option with <platform name>. Please be sure to evaluate the customer’s security requirements and add to the configuration as necessary.
All G10 Platforms, All G9 Platforms Applicable for NX-G9 for now and will extend to NX-G8 also in future NPI-894
NPI-1439
Historical Rules 100 Below messages should be present in Quote Document based in whether TPM is selected or not selected in the configuration that is quoted:

With TPM:
This <platform name> configuration quote includes the TPM 2.0, a security hardware, which may be leveraged to support a security feature. Kindly verify this configuration aligns with your security plan.

Without TPM:
This <platform name> configuration quote does not include the TPM 2.0, a security hardware, which may be leveraged to support a security feature. Kindly verify this configuration aligns with your security plan.

All G10 Platforms, All G9 Platforms Applicable for NX-G9 for now and will extend to NX-G8 also in future NPI-894
NPI-1439
G9 Phase 1 | Section 1 : New G9 Rules 1 NX Appliance is not supported on G9 platforms. If an Appliance quote hits Frontline through another system /API – system should block that quote and throw error message:
If G8 systems are still quotable: “NX Appliance quote type is not supported for G9 platforms. Please quote G9 platforms as NX Core. Alternatively, you can quote G8 platforms as NX Appliance”
If G8 systems are not quotable (Inactive): ““NX Appliance quote type is not supported for G9 platforms. Please quote G9 platforms as NX Core.”
All G8 Platforms, All G9 Platforms NPI-761
G9 Phase 2 | Section 2: New G9 Rules 1 As specified in G9 BRD: HBA is a new selectable component in the workflow for NX-8155-G9, NX-8170-G9, NX-3155-G9, NX-8155A-G9, NX-1175S-G9 (All G9 platforms except 1065-G9,3060-G9,3035-G9,8150-G9).

The HBA component visibility is dependent on drive selected.

HBA should be selectable if one of the drives is either HDD or SSD (incl. encrypted parts). HBA should NOT be selectable for All NVMe / All NVMe SED drive configuration.

All G9 Platforms NPI-762
NPI-764
G9 Phase 2 | Section 2: New G9 Rules 2 For NX-8170-G9, 100GbE NIC should not be allowed with 128GB Memory option.
Message: “100GbE NIC is not allowed with 128 GB Memory for NX-8170-G9.”
NX-8170-G9 Override functionality Required NPI-762
NPI-1411
G9 Phase 2 | Section 2: New G9 Rules 3 For NX-8170-G9, If HBA is available and selected for the chosen drive configuration: Quantity option available for all AOC NIC reduces by 1, except 100GbE NIC

Error message:: “Please note for All SSD drive configuration, you can select a maximum of 2 NIC cards. Switch over to All NVMe, if you want 3 NIC cards in your system.”

Example: If HBA NOT selected C-NIC-25G2D1 will have quantity options as 1,2 and 3 per product options available C-NIC-100G2E1 will have quantity options as 1,2 per product options available

If HBA selected C-NIC-25G2D1 will have quantity options as 1,2 (1 less per product options available) C-NIC-100G2E1 will have quantity options as 1,2 per product options available

21-Jan-25: FYI, NIC is not a mandatory component for NX-8170-G9

NX-8170-G9 NPI-762
G9 Phase 2 | Section 2: New G9 Rules 4 8155-G9 and 8155A-G9
On a partially configured node, for hybrid configurations with a replication requirement (i.e. RPO-1Hr, RPO-6Hr):
15.36 TB NVMe/ SSD should not be allowed with HDD capacity >=12 TB
Message: “For <xx TB <HDD/HDE> capacity, 15.36 TB<SSD or NVMe> capacity is allowed on <8155/8155A> partially configured node only with no snapshots.”

The rule should also apply to SSE and NVMe SED (post-GA).

NX-8155-G9, NX-8155A-G9 Override functionality Required NPI-762
G9 Phase 2 | Section 2: New G9 Rules 5 8155 specific rules in NPI-735 under Section 5.2 and Section 5.3 should extend to 8155A-G9 as well – BRD
This extends to the warning/error messages i.e. whenever a rule gets triggered for 8155A – the messaging should say 8155A and not 8155.
NX-8155-G9, NX-8155A-G9 Override functionality required NPI-762
G9 Phase 3 | Section 3: New G9 rules 1 GPU & NIC related option constraints for Platform NX-3155-G9.
Please note that these rules should apply only to Nvidia T4 (C-GPU-T4-16GB), A2 (C-GPU-A2-16GB) and Nvidia L4 (C-GPU-L4-24GB) GPUs for Hybrid / All SSD configuration

Table Link

NX-3155-G9 NPI-764
NPI-942
G9 Phase 3 | Section 3: New G9 rules 2 GPU & NIC-related option constraints for Platform NX-3155-G9 | This rule applies only to A series GPUs (except A2), Nvidia L40s GPU, Nvidia L40, Nvidia H100, Nvidia H100-NVL GPU for Hybrid / All SSD configuration

Table Link

*Nvidia L40s GPU, Nvidia L40, Nvidia H100, Nvidia H100-NVL GPU for Hybrid / All SSD configuration are part of the above rule & not the except list

NX-3155-G9
G9 Phase 3 | Section 3: New G9 rules 3 GPU & NIC related option constraints for Platform NX-1175S-G9.

Table Link

NX-1175S-G9
G9 Phase 3 | Section 3: New G9 rules 4 For 1175S Hybrid configuration (NVMe + HDD) | This rule applies for RPO-1Hr, RPO-6Hr and No Snapshot RPO 24-Hr
If nodes are configured with 2 NVMe + 2 HDDs configuration, the NVMe capacity should be a minimum of 30 % or more of the overall node capacity.”
When this percentage is calculated round up the percentage to the whole number
NX-1175S-G9 Override functionality Required NPI-764
G9 Phase 3 | Section 3: New G9 rules 5 For 1175S-G9: If All Flash drive configuration is chosen then minimum 4 quantity of 32GB memory must be selected NX-1175S-G9 NPI-764
NPI-1015
G9 Phase 3 | Section 3: New G9 rules 6 For 1175S-G9: When C-CPU-5415+ is selected below message should fire
“Please note 5415+ CPU is excluded from Energy Star certification”
NX-1175S-G9 NPI-764
G9 Phase 3 | Section 3: New G9 rules 7 When the CPU which is not Energy Star compliant for a particular platform is selected then fire the below warning message
“Please note <CPU name> is excluded from Energy Star certification for <Platform Name>”
All G9 Platforms, All G8 Platforms Applicable for NX-G9 for now and will extend to NX-G8 also in future NPI-900
NPI-1015
G9 Phase 3 | Section 3: New G9 rules 8 Below message to be displayed in the Frontline choose Hardware specification page beside “+ Add TPM”
“TPM is optional and is not selected by default. Please select based on the customer’s security requirement.””
All G9 Platforms, All G8 Platforms Applicable for NX-G9 for now and will extend to NX-G8 also in future NPI-894
G9 Phase 3 | Section 3: New G9 rules 9 Below message should fire in Frontline UI Summary page:

TPM 2.0 is offered as a security hardware option with <platform name>. Please be sure to evaluate the customer’s security requirements and add to the configuration as necessary.

All G9 Platforms, All G8 Platforms Applicable for NX-G9 for now and will extend to NX-G8 also in future NPI-894
G9 Phase 3 | Section 3: New G9 rules 10 Below messages should be present in Quote Document based in whether TPM is selected or not selected in the configuration that is quoted:

With TPM:
This <platform name> configuration quote includes the TPM 2.0, a security hardware, which may be leveraged to support a security feature. Kindly verify this configuration aligns with your security plan.

Without TPM:
This <platform name> configuration quote does not include the TPM 2.0, a security hardware, which may be leveraged to support a security feature. Kindly verify this configuration aligns with your security plan.

All G9 Platforms, All G8 Platforms Applicable for NX-G9 for now and will extend to NX-G8 also in future NPI-894
G9 Phase 3 | Section 3: New G9 rules 11 In 8155-G9 and 8155A-G9 for Hybrid Configuration (HDD + SSD/ HDD + NVMe)

24TB HDD should be available for selection only if NUS Dedicated Cluster/ Files and Objects Dedicated Cluster is selected. It should not be available for selection if NCI Cluster/AOS Cluster is selected.

For NUS Dedicated Cluster/ Files and Objects Dedicated Cluster:

Quantity 2 of 3.84TB SSD/NVMe should not be allowed for selection with 24TB HDD and below error should fire:

“Select quantity 4 of 3.84TB SSD/NVMe. If quantity 2 SSD/NVMe is desired then select capacity >= 7.68TB SSD/NVMe”

NX-8155-G9 NPI-940
G9 Phase 3 | Section 3: New G9 rules 12 GPU & NIC related option constraints for Platform NX-3155-G9.
Please note that these rules should apply only to Nvidia T4 (C-GPU-T4-16GB), A2 (C-GPU-A2-16GB) and Nvidia L4 (C-GPU-L4-24GB) GPUs for All NVMe configuration

Table Link

NX-3155-G9 NPI-942
G9 Phase 3 | Section 3: New G9 rules 13 GPU & NIC related option constraints for Platform NX-8155A-G9 with All NVMe configuration (No HBA).

Table Link

NX-8155A-G9 NPI-1107
G9 Phase 3 | Section 3: New G9 rules 14 GPU & NIC-related option constraints for Platform NX-3155-G9 | This rule applies only to A series GPUs (except A2), Nvidia L40s GPU, Nvidia L40, Nvidia H100, H100-NVL GPU for All NVMe configuration

Table Link

NX-3155-G9 NPI-946
NPI-945
NPI-944
NPI-1302
G9 Phase 3 | Section 3: New G9 rules 15 GPU & NIC-related option constraints for Platform NX-8155A-G9 | This rule applies to NVIDIA L4, NVIDIA A16 GPUs under All Nvme & Nvme + SSD (and all configs that allow for NIC & GPU selection)

Table Link

NX-8155A-G9 NPI-946
NPI-945
NPI-944
NPI-1302
G9 Phase 3 | Section 3: New G9 rules 16 Introduce new PCIe Gen 5 – PM9D3a SKUs -C-NVM-3.84TB-AB-A, C-NVM-7.68TB-AB-A & C-NVM-15.36TB-AB-A.
These drives will be supported:
1. For EMR CPUs only under platforms 8170-G9, 8150-G9, 8155-G9, 3155-G9
2. For SPR & EMR under platform 1175S-G9
3. For SPR & EMR under platform 1150S-G9
4. For AMD under platform 8155A-G9

Error message to be shown if a user selects an SPR CPU with these SKUs for 8170,8150,8155,3155 platforms:
“PCIe Gen5 NVMe drive is not offered with ‘Sapphire Rapids’ processor for NX-8170-G9, NX-8150-G9, NX-8155-G9, NX-3155-G9”

NX-8170-G9, NX-8150-G9, NX-8155-G9, NX-3155-G9, NX-1175S-G9, NX-1150-G9, NX-8155A-G9 NPI-1351
G9 Phase 3 | Section 3: New G9 rules 17 With NPI-1410, new NVME SED SKUs are being introduced.
List of SKUs – C-NVE-3.84TB-A, C-NVE-7.68TB-A, C-NVE-15.36TB-A
NVME SED Rules
1. Intermixing Rules
1.1 Model Types leveraged
1.1.1 All NVMe & NVMe + SSD – for NVMe SEDs
1.1.2 Hybrid – for (NVMe SED + HDD SED)
1.2 Mixing (NVMe SED + NVMe) is not supported
1.3 Mixing (NVMe SED + HDD) is not supported
1.4 NVMe SED + SSD SED is not supported
2. The drives will be supported for
2.1 Only EMR CPUs for platforms NX-3155-G9, NX-8150-G9, NX-8155-G9, NX-8170-G9
2.2 Both SPR and EMR CPUs for NX-1175S-G9, NX-1150S-G9
3. AOS 7.3 BRD Rules Apply

Apr 30: “NVMe SEDs are not supported with “Sapphire Rapids” processors for NX-3155-G9, NX-8150-G9, NX-8155-G9, NX-8170-G9”

25 June 25: Whenever NVMe SEDs are selected, a message to be displayed “AOS 7.3 (or higher) is required for NVMe SED support”

NX-8170-G9, NX-8150-G9, NX-8155-G9, NX-3155-G9, NX-1175S-G9, NX-1150-G9 NPI-1410 25-June-2025
G9 Phase 4 | Section 4: G9 EMR+ components rules, 9151-G9 and 1150S-G9 1 If any of the 32GB, 64GB, 96GB DDR5-5600 DIMM is selected with Sapphire Rapids processor, then below error should fire:

“If the user wants DDR5-5600 memory, then select the Intel 5th Generation ‘Emerald Rapids’ processor.”

“DDR5-5600 memory is not supported with ‘Sapphire Rapids’ processor. Select the Intel 5th Generation ‘Emerald Rapids’ processor instead”

Above rule is not applicable to NX-1150S-G9 platform & AMD platform 8155A-G9 (added AMD platform on June 25)

Enable to 32Gb and 64GB DDR5-5600 for all SPR SKU

The above message will need to be modified and restricted to only when 96GB DDR5-5600 DIMM is selected with Sapphire Rapids processor,
“96 GB DDR5-5600 memory is not supported with ‘Sapphire Rapids’ processor. Select the Intel 5th Generation ‘Emerald Rapids’ processor instead”

Above rule is applicable for 1150s-G9.
FYI – 128GB DDR5-4800 is supported with EMR, no changes there.

All G9 Platforms NPI-1015
NPI-1208
G9 Phase 4 | Section 4: G9 EMR+ components rules, 9151-G9 and 1150S-G9 2 Below pop up message should fire only if NX-8155-G9, NX-8155A-G9 and NX-3155-G9 platforms are quoted. The message should pop up as soon as the platform is selected while in the configuration page:
“Default rails kits for NX-3155-G9, NX-8155-G9 and NX-8155A-G9 platforms have a longer nominal length as compared to other G9 platforms. For more information, please refer to this documentation. If a shorter rail kit is preferred then please select U-RAIL-1U-D.”

Below pop up message should fire only if NX-8155-G9, NX-8155A-G9 and NX-3155-G9 platforms are quoted. The message should pop up as soon as the platform is selected while in the configuration page:
“Default rails kits for NX-3155-G9, NX-8155-G9 and NX-8155A-G9 platforms have a longer nominal length as compared to other G9 platforms. For more information, please refer to this documentation. If a shorter rail kit is preferred then please select U-RAIL-1U-D.”

11Mar2025: The link is updated in the above change

NX-8155-G9, NX-8155A-G9, NX-3155-G9 Applicable to NX-8155-G9, NX-8155A-G9 and NX-3155-G9 platforms NPI-1142
BA-108568
G9 Phase 4 | Section 4: G9 EMR+ components rules, 9151-G9 and 1150S-G9 3 Below pop up message should fire only if NX-9151-G9 platform is quoted. The message should pop up as soon as the platform is selected while in the configuration page:
“The chassis depth of the NX-9151-G9 platform is 900mm (35.4 inch). It is advised to use a rack with 1200mm depth.For more information, please refer to this documentation.”
“The NX-9151-G9 chassis depth is 900 mm (35.4 in.). Mount the chassis in a rack with a minimum depth of 1200 mm (47.24 in.). For more information, please refer to this documentation.”

“The NX-9151-G9 chassis depth is 900 mm (35.4 in.). Mount the chassis in a rack with a minimum depth of 1200 mm (47.24 in.). For more information, please refer to this documentation.”

11Jun2025: Link further updated to exact section
12Mar2025: The link is updated in the above change

NX-9151-G9 Applicable to NX-9151-G9 platform NPI-1142
BA-108568
G9 Phase 4 | Section 4: G9 EMR+ components rules, 9151-G9 and 1150S-G9 4 If Emerald Rapids processor is selected then below mentioned GPUs should not be available for selection in the GPU dropdown.
C-GPU-T4-16GB
C-GPU-T4-16GB-CM
C-GPU-A2-16GB
C-GPU-A2-16GB-CM
C-GPU-A40-48GB-A
C-GPU-A40-48GB-A-CM
All G9 Platforms NPI-1015
G9 Phase 4 | Section 4: G9 EMR+ components rules, 9151-G9 and 1150S-G9 5 Disable 32GB or 64GB DDR5-4800 with EMR processors only 128GB DDR5-4800 is supported with EMR
Remove the 32Gb and 64GB DDR5-4800 for all SPR SKU –
*Exception of 64GB to be allowed with 9151-G9 platform & both 32 & 64 GB to be allowed with 8155A-G9
*Exception 128GB DDR5-4800 is not supported with NX-9151-G9 EMR
All G9 Platforms NPI-1208
NPI-1409
G9 Phase 4 | Section 4: G9 EMR+ components rules, 9151-G9 and 1150S-G9 6 When the CPU which is not Energy Star compliant for a particular platform is selected then fire the below warning message
“Please note <CPU name> is excluded from Energy Star certification for <Platform Name>”
For NX-1150S G9, the following CPUs are not Energy Star Compliant C-CPU-3408U and C-CPU-4509Y
All G9 Platforms, All G8 Platforms NPI-1054
G9 Phase 4 | Section 4: G9 EMR+ components rules, 9151-G9 and 1150S-G9 7 GPU & NIC-related option constraints for Platform NX-1150S-G9 for All NVMe configuration

Table Link

NX-1150-G9 NPI-1054
G9 Phase 4 | Section 4: G9 EMR+ components rules, 9151-G9 and 1150S-G9 8 NX-9151-G9 (MGX Phase 2) – Rules on NIC & GPU
C-NIC-200G2A1 & C-NIC-200G2A1-Q – Mellanox CX7 : will be supported only with EMR processors
C-GPU-H100-NVL – will be supported only with EMR processors

C-NIC-100G2A2 & C-NIC-100G2A2-Q- is supported only with SPR processors
C-GPU-L40S-48GB-B – is supported only with SPR processors

30Jan25 – C-GPU-L40S-48GB-B is supported with both SPR and EMR processors
27Oct25 – C-NIC-100G2A2 & C-NIC-100G2A2-Q is supported with both SPR and EMR Processors

NX-9151-G9 NPI-1298
NPI-1350
NPI-1707
27-Oct-2025
G9 Phase 4 | Section 4: G9 EMR+ components rules, 9151-G9 and 1150S-G9 9 C-MEM-64GB-5600-S on NX-9151-G9 MGX
C-MEM-64GB-5600-S and C-MEM-64GB-5600-S-CM will only be supported by EMR processors for NX-9151-G9.

C-MEM-128GB-4800 on NX-9151-G9 MGX
C-MEM-128GB-4800 and C-MEM-128GB-4800-CM will only be supported by SPR processors for NX-9151-G9.

NX-9151-G9 NPI-1409
G9 Phase 5 | Section 4: G9 Compute-Only Configurations 1 HBA is not a valid component in zero-drive compute-only configuration. HBA should not appear as a selectable component when compute only model type is selected for these platforms All G9 Platforms NPI-1210
NPI-1349
G9 Phase 5 | Section 4: G9 Compute-Only Configurations 2 NIC-GPU rules for NX-8170-G9 , NX-8155-G9 , NX-1175S-G9 Compute-Only Model Type are as follows –

Table Link

**Note – 3 NICs are not supported when 100GbE NIC is selected with NX-8170-G9 (Refer: G9 Phase 2 | Section 2: New G9 rules)

NX-8155-G9, NX-8170-G9, NX-1175S-G9 NPI-1349
G10 Phase 1: G10 Rules 1 As specified in G10 BRD:
HBA is a selectable component in the workflow for NX-8170-G10

The HBA component visibility is dependent on the drive selected.

HBA should be selectable if one of the drives is either HDD or SSD (incl. encrypted parts). HBA should NOT be selectable for All NVMe / All NVMe SED drive configuration.

NX-8170-G10 NPI-1408 10-Mar-2025
G10 Phase 1: G10 Rules 2 For NX-8170-G10, 100GbE and 200GbE NIC should not be allowed with 128GB Memory option.
Message: “100GbE and 200GbE NIC is not allowed with 128 GB Memory for NX-8170-G10.”
NX-8170-G10 To have override functionality NPI-1408 26-Mar-2025 29-May-2025
G10 Phase 1: G10 Rules 5 Ultimate license or encryption add-on is required for adding SED drives
For new portfolio quote:
Ultimate license (NCI/NCI-D/EUC ULT) or security addon (NCI/NCI-D/NUS Security) is required for adding SED drives
Needs to apply for NVMe SED also in future
All G10 Platforms NPI-1408 10-Mar-2025
G10 Phase 1: G10 Rules 6 GPU & NIC Mixing rules for NX-8150G-G10:
When GPU is FHFL GPU (A16, L40S, H100 NVL, H200 NVL, B300, RTX Pro 6000 BSE…more to come based on NVIDIA roadmap)

Table Link

NX-8150G-G10 NPI-1408 10-Mar-2025 5-Sep-2025
G10 Phase 1: G10 Rules 7 GPU & NIC Mixing rules for NX-8150G-G10:
When GPU is L4 GPU, B10 GPU

Table Link

NX-8150G-G10 NPI-1408 10-Mar-2025
G10 Phase 1: G10 Rules 8 For NX-8170-G10, If HBA is available and selected for the chosen drive configuration:
Quantity option available for all AOC NIC reduces by 1
Error message:: “Please note for All SSD drive configuration, you can select a maximum of 2 NIC cards. Switch over to All NVMe, if you want 3 NIC cards in your system.”

Example:
If HBA NOT selected
C-NIC-25G2D1 will have quantity options as 1,2 and 3 per product options available
If HBA selected
C-NIC-25G2D1 will have quantity options as 1,2 (1 less per product options available)
The above applies for all NICs supported with NX-8170-G10

For NX-8170-G10, If HBA is available and selected for the chosen drive configuration: The max quantity available for all AOC Nics is 2. This applies for all NICs.

Error message:: “Please note for All SSD drive configuration, you can select a maximum of 2 NIC cards. Switch over to All NVMe, if you want 3 NIC cards in your system.”

Example:
If HBA NOT selected
C-NIC-25G2D1 will have quantity options as 1,2 and 3 per product options available
C-NIC-100G2A2 will have quantity options as 1 and 2 per product options available

If HBA selected
C-NIC-25G2D1 will have quantity options as 1,2
C-NIC-100G2A2 will have quantity options as 1,2

NX-8170-G10 NPI-1408 10-Mar-2025 12-May-2025
G10 Phase 1: G10 Rules 9 200GbE (eg. C-NIC-200G2A1 Mellanox (CX7)) cannot be mixed with 100GbE NIC (eg. C-NIC-100G2E1, C-NIC-100G2A2)

12June25 – NIC Mixing has been added as G10 Phase 2 & Phase 3 rules – Rule 11

All G10 Platforms NPI-1408 27-Mar-2025
G10 Phase 1: G10 Rules 10 NX-8150G-G10 will support the H100 NVL GPU. 8150G-G10 will have a different OT (operating temperature) if H100 NVL GPU is selected. We will need a message in FL to trigger when the H100 NVL GPU is selected with this platform.

Message: “NX-8150G-G10 supports an ambient temperature of 25°C with C-GPU-H100-NVL”

NX-8150G-G10 NPI-1408 6-May-2025 9-Jul-2025
G10 Phase 1: G10 Rules 11 Display below message when U-GPU-H100-NVL is being quoted.

Message: “NX-8150G-G10 supports an ambient temperature of 25°C with U-GPU-H100-NVL”

NX-8150G-G10 NPI-1408 6-May-2025 9-Jul-2025
G10 Phase 2: G10 Rules 1 As specified in G10 BRD:
HBA is a selectable component in the workflow for NX-1175S-G10 , NX-3035-G10

The HBA component visibility is dependent on the drive selected.

HBA should be selectable if one of the drives is either HDD or SSD (incl. encrypted parts). HBA should NOT be selectable for All NVMe / All NVMe SED drive configuration.

NX-1175S-G10, NX-3035-G10 NPI-1439
NPI-1458
1-June-2025
G10 Phase 2: G10 Rules 3 For 1175S-G10 Hybrid configuration (NVMe + HDD) | This rule applies for RPO-1Hr, RPO-6Hr and RPO 24 – Hr
“If nodes are configured with 2 NVMe + 2 HDDs configuration, the NVMe capacity should be a minimum of 30 % or more of the overall node capacity.”
When this percentage is calculated round up the percentage to the whole number
NX-1175S-G10 Override functionality required NPI-764
NPI-1439
1-June-2025
G10 Phase 2: G10 Rules 4 For 1175S-G10: If All Flash drive configuration is chosen then minimum 4 quantity of 32GB memory must be selected

This applies to NVME and NVME SED All-Flash as well

NX-1175S-G10 NPI-764
NPI-1015
NPI-1439
1-June-2025 8-Jul-2025
G10 Phase 2: G10 Rules 5 GPU & NIC-related option constraints for Platform NX-8155AS-G10 | This rule applies to NVIDIA L4, NVIDIA A16, B10 GPUs under NVME All Flash (and all configs that allow for NIC & GPU selection)

Table Link

NX-8155AS-G10 NPI-1439 1-June-2025
G10 Phase 2: G10 Rules 8 GPU & NIC related option constraints for Platform NX-1175S-G10. Please note that these rules should apply only for Hybrid configuration

Table Link

NX-1175S-G10 NPI-1439 1-June-2025
G10 Phase 2: G10 Rules 9 GPU & NIC related option constraints for Platform NX-1175S-G10. Please note that these rules should apply only for NVME All-Flash configuration

Table Link

NX-1175S-G10 NPI-1439 1-June-2025
G10 Phase 2: G10 Rules 10 NX-8155AS-G10 – When GPU is selected, a maximum of 8 NVMe drives can only be selected.
Message : “When GPU is selected, max 8 NVMe drives are allowed”
NX-8155AS-G10 NPI-1439 1-June-2025
G10 Phase 2: G10 Rules 11 For all NX-G10 platforms, we can support multiple (heterogeneous nics) on the same platform, as long as the total nic count is within max supported quantity.
These nic-nic combinations are supported along with the specific AIOM/LOM selection as mentioned in the supported list below.

Supported NIC-NIC mixing SKUS –
1. C-NIC-25G2A2 (and C-NIC-25G2A2-Q) with C-NIC-10G4B1BT when AIOM is C-LOM-10G2B1BT
2. C-NIC-25G2A2 (and C-NIC-25G2A2-Q) with C-NIC-10G2D1BT when AIOM is C-LOM-10G2D1BT (post-GA)
3. Other heterogeneous combinations with multiple nics are not supported
4. Exception – 1175S-G10 will not support nic mixing as there is no AIOM/LOM
5. AIOM/LOMs must be homogenous
6. Every supported NIC can be homogeneous (including C-NIC-25G2A2, C-NIC-10G4B1BT, C-NIC-10G2D1BT)

For all other nic SKUs, we only support homogenous nics (no combination of multiple NIC SKUs in the same platform).

G10 platform nic mixing rules – https://docs.google.com/spreadsheets/d/1ZWHFCt5jeCPLG1DnNJtCFFJ0Syh12p-eKuHEG95vpXQ/edit?gid=512855463#gid=512855463


12-Nov-2025 update (added nic mixing combination number 2)
For all NX-G10 platforms, we can support multiple (heterogeneous nics) on the same platform, as long as the total nic count is within max supported quantity.
These nic-nic combinations are supported along with the specific AIOM/LOM selection as mentioned in the supported list below.

Supported NIC-NIC mixing SKUS –
1. C-NIC-25G2A2 (and C-NIC-25G2A2-Q) with C-NIC-10G4B1BT when AIOM is C-LOM-10G2B1BT
2. C-NIC-25G2A2 (and C-NIC-25G2A2-Q) with C-NIC-10G2D2BT when AIOM is C-LOM-10G2D1BT
3. Other heterogeneous combinations with multiple nics are not supported
4. Exception – 1175S-G10 will not support nic mixing as there is no AIOM/LOM
5. Every supported NIC can be homogeneous (including C-NIC-25G2A2, C-NIC-10G4B1BT, C-NIC-10G2D1BT)

For all other nic SKUs, we only support homogenous nics (no combination of multiple NIC SKUs in the same platform).

G10 platform nic mixing rules – https://docs.google.com/spreadsheets/d/1ZWHFCt5jeCPLG1DnNJtCFFJ0Syh12p-eKuHEG95vpXQ/edit?gid=512855463#gid=512855463

All G10 Platforms NPI-1439
NPI-1721
1-June-2025 12-November-2025
G10 Phase 2: G10 Rules 12 Below pop up message should fire only if NX-8155AS-G10 or NX-8170A-G10 platforms are quoted. The message should pop up as soon as the platform is selected while in the configuration page:
“Default rails kits for NX-8155AS-G10 or NX-8170A-G10 platforms have a longer nominal length as compared to other G10 platforms. For more information, please refer to this documentation. If a shorter rail kit is preferred then please select U-RAIL-1U-D.”

Link above will change and should be available in a few days. Putting this as placeholder meanwhile as we need the popup message to fire.

NX-8155AS-G10, NX-8170A-G10 NPI-1439 14-Jul-2025 22-Jul-2025
G9 Phase 4 | Section 4: G9 EMR+ components rules, 9151-G9 and 1150S-G9 10 When NVIDIA RTX Pro 6K (C-GPU-RTXP6KBSE-96GB) is quoted with NX-9151-G9, a message should be triggered
“RTX Pro 6000 BSE GPU with the NX-9151-G9 will operate at 450W instead of its maximum 600W. As a result, you can expect a performance reduction of approximately 6–12%, depending on the workload.”

When NVIDIA RTX Pro 6K (C-GPU-RTXP6KBSE-96GB) is quoted with NX-9151-G9, a message should be triggered
“When used with the NX-9151-G9, the RTX Pro 6000 BSE GPU operates at 450W instead of its maximum 600W, which may result in an estimated performance reduction of approximately 6–12%, depending on the workload.”

NX-9151-G9 NPI-1561 21-Jul-2025 28-Jul-2025
G9 Phase 4 | Section 4: G9 EMR+ components rules, 9151-G9 and 1150S-G9 11 For NX-8170-G9, NX-8150-G9, NX-8155-G9, and NX-3155-G9 , when the CPUs C-CPU-4510 or C-CPU-4509Y are added alongwith a PCIe Gen5 NVMe drive (C-NVM-3.84TB-AB-A , C-NVM-7.68TB-AB-A, C-NVM-15.36TB-AB-A) , then the following message should trigger

“PCIe Gen5 drives configured with EMR CPU 4510 or 4509Y in NX-8170-G9, NX-8150-G9, NX-8155-G9, or NX-3155-G9 will operate at PCIe Gen4 speed”

This needs to be added as the amber banner on quote screen. Additionally, it should also be displayed as a warning/popup under NVMe selection on config screen when this particular combination is selected.

NX-8150-G9, NX-8170-G9, NX-8155-G9, NX-3155-G9 NPI-1585 31-Jul-2025 4-Sep-2025
G10 Phase 3: G10 Rules 1 As specified in G10 BRD:
HBA is a selectable component in the workflow for NX-3035-G10

The HBA component visibility is dependent on the drive selected.

HBA should be selectable if one of the drives is either HDD or SSD (incl. encrypted parts). HBA should NOT be selectable for All NVMe / All NVMe SED drive configuration.

NX-3035-G10 NPI-1458 21-Aug-2025
G10 Phase 1: G10 Rules 12 When NVIDIA RTX Pro 6K (C-GPU-RTXP6KBSE-96GB) is quoted with NX-8150G-G10, the following 2 messages should be triggered
1. “When used with the NX-8150G-G10, the RTX Pro 6000 BSE GPU operates at 450W instead of its maximum 600W, which may result in an estimated performance reduction of approximately 6–12%, depending on the workload.”
2. “When the RTX Pro 6000 BSE GPU is added to NX-8150G-G10, the platform will have a max operating temperature of 25C”

When Upgrade RTX Pro 6K GPU (U-GPU-RTXP6KBSE-96GB) is selected, the following 2 messages should be triggered
1. “When used with the NX-8150G-G10, the RTX Pro 6000 BSE GPU operates at 450W instead of its maximum 600W, which may result in an estimated performance reduction of approximately 6–12%, depending on the workload. Please ensure memory quantity on the NX-8150G-G10 node is 16 or lesser if you plan to populate 2 quantity of RTX Pro 6000 BSE GPU”
2. “When the RTX Pro 6000 BSE GPU is added to NX-8150G-G10, the platform will have a max operating temperature of 25C”

This needs to be added as the amber banner message on the quote screen.

NX-8150G-G10 NPI-1626 5-Sep-2025 11-Sep-2025
G10 Phase 1: G10 Rules 13 NX-8150G-G10 with RTX Pro 6000 BSE GPU (C-GPU-RTXP6KBSE-96GB)

For NX-8150G-G10, when 24 or 32 quantity of Memory is selected, a maximum of 1x RTX Pro 6000 BSE GPU is selectable.
Error message when 2x RTX Pro 6000 BSE GPU is selected and memory quantity is 24 or 32 –
“Max 16 DIMMs allowed in NX-8150G-G10 with 2 quantity of RTX Pro 6000 BSE GPU. Alternatively, you may select 1 quantity of RTX Pro 6000 BSE GPU for higher quantity of DIMMs”

For NX-8150G-G10, when 8 or 16 quantity of memory is selected, the user can select upto 2x RTX Pro 6000 BSE GPU with no error message.

NX-8150G-G10 NPI-1626 5-Sep-2025
G9 Phase 4 | Section 4: G9 EMR+ components rules, 9151-G9 and 1150S-G9 12 To enable worldwide quotability for NX-9151-G9

For US (non-FED) and EU countries – Only PRD Support Option should be visible and selectable for NX-9151-G9
For US (FED) – Only FED PRD Support Option should be visible and selectable for NX-9151-G9
For All other countries – Only NBS support option should be visible and selectable for NX-9151-G9

Whenever NBS is quoted on NX-9151-G9, the following message should appear on Frontline
The NX-9151-G9 has “Production Level” support only in the US and EU. In other regions, hardware support level is “Next Business Day Ship”. Parts are shipped from depots outside the region, with delivery subject to shipping and customs processing times.

NX-9151-G9 NPI-1658 26-Sep-2025